This is an old revision of the document!
Image | Vendor | Model | Year | kV | Gun | Resolution (nm) | Features | List price | Ask price | Manual | Schem | SW | Notes |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Source: [TNTech MSE] | ISI | SR50 | |||||||||||
Source: [UMT EA] | ISI | CL-6 | |||||||||||
Source: [DS130 DS130] | ISI | DS130 | |||||||||||
Source: [dtradingpost ISI-40] | ISI | ISI-40 | |||||||||||
ISI | ISI-100 | 1977 | 25? | LAB6 | 10? | “could handle 4-inch-diameter specimens” [1970s] | |||||||
Source: [PTLI ISI-SS40] | ISI | ISI-SS40 | |||||||||||
ISI | ISI-60 | 1979 | <$30,000 (1979) [isi research advert] | Advert lists it as new the same time as the Super IIIA and I know the Super IIIA was around 1979 | |||||||||
Source: [AMS SEM] | ISI | ISI-SS60 | |||||||||||
Source: private e-mail | ISI | M-7 | Very hard to find info on this unit | ||||||||||
Source: [OSU MINISEM1] | ISI | MSM-2 | 1973 | 30 | $17,000 | Tabletop [OSU MINISEM1] |
|||||||
ISI | Super-Mini-SEM 1 (SMS-1) | 1974 | 25 | 10 | Yes | “could accommodate samples up to 32 mm in diameter” [1970s] | |||||||
ISI | Super-Mini-SEM 2 (SMS-2) | 1975 | 25? | 10? | Yes | “increased the sample chamber size to 3 inches in diameter”[1970s] JM may have partial or full schematic |
|||||||
ISI | Super-Mini-SEM (SMS-3A) “Super III A” | ~1980 | 30 | WHP | 7 | <$30,000 (1979) [isi research advert] | Yes | Yes | ref |
||||
Source: [Virago] | ISI | SX30 | [Virago] | ||||||||||
Source: [equipmatching] | ISI | SX-40 | 30 | 6 | Yes | Thanks to Nathalie Renevier for the user manual! Specifications on page 67 |
|||||||
SX-60 | Mentioned on ds130 website but I can't find any other references to this model | ||||||||||||
ISI | TV Mini-SEM (TV-MSM) Schematic: MRS-2 | 1976 | Yes | Noisebridge unit Year based off of schematic date |
|||||||||
Source: [eBay 231289327125] | ISI | WB-6 | |||||||||||
JEOL | ClairScope JASM-6200 | W/8nm (30kV) | Atmospheric | ||||||||||
JEOL | JAMP-10 | ||||||||||||
JEOL | JIB-4500 | Multibeam FIB | |||||||||||
JEOL | JIB-4600F | Multibeam FIB | |||||||||||
JEOL | JEM-100S | 14999 20,000 | [1960s] | ||||||||||
JEOL | JEM-ARM-1000 | 1983 | 1000 | “one-of-a-kind Ultrahigh Voltage EM for the Lawrence Berkeley Laboratories in California, where scientists were interested in atomic resolution” [1980s] | |||||||||
JEOL | JFSM-30 | 1974 | FE | 3 | [1970s] | ||||||||
JEOL | JRSM-50A | 1973 | “hot stage for examining samples at elevated temperatures” [1970s] | ||||||||||
JEOL | JSM-1 | 50 | 50 | [1960s] | |||||||||
JEOL | JSM-2 | 50 | [1960s] | ||||||||||
JEOL | JSM-U | 50 | [1960s] | ||||||||||
JEOL | JSM-35CF | 4,900 used 10/05/2013 | |||||||||||
JEOL | JSM-35CFS | 1982/3? | [1980s] | ||||||||||
JEOL | JSM-820 | ||||||||||||
JEOL | JSM-840 | 1982/3? | 3 | 3900 | “best i've gotten out of it was resolving ~60nm colloidal silica particles” [az] year: [1980s] |
||||||||
JEOL | JSM-5200 | 18950 | |||||||||||
JEOL | JSM-5400 | ||||||||||||
JEOL | JSM-5800 | ||||||||||||
JEOL | JSM-5900 | 6000 | |||||||||||
Source | JEOL | JSM-5900LV | 3nm @ 30kV (SEI) 5nm @30kV (BEI) | ||||||||||
JEOL | JSM-5910 | ||||||||||||
JEOL | JSM-6010LA | HV: 4nm @ 20kV (SE) LV: 5nm @ 20kV (BSE) | |||||||||||
JEOL | JSM-6010PLUS “JSM-6010PLUS InTouchScope” | ||||||||||||
JEOL | JSM-6100 | 10,000 | |||||||||||
JEOL | JSM-6300F | CFE | 1.5 nm @ 30 kV | ||||||||||
JEOL | JSM-6300LV | ||||||||||||
JEOL | JSM-6300V | 9500 | |||||||||||
JEOL | JSM-6340F | CFE | 2.5 nm @ 1 kV 1.2 nm @ 20 kV | ||||||||||
JEOL | JSM-6390 | ||||||||||||
JEOL | JSM-6390LV | ||||||||||||
JEOL | JSM-6400 | 10,000 11,000 | |||||||||||
Source | JEOL | JSM-6460 | ~2004 | ||||||||||
JEOL | JSM-6510 | LV: 3nm @ 30kV (SE) | |||||||||||
JEOL | JSM-6510LV | HV: 3nm @ 30kV (SE) LV: 4nm @ 30kV (BSE) | |||||||||||
JEOL | JSM-7100F | 1.2nm at 30kV | |||||||||||
JEOL | JSM-7500F | x 25 to 1,000,000 (printed as a 120mm x 90mm micrograph) | |||||||||||
JEOL | JSM-7610F | 1.0 nm (15 kV), 0.6 nm (30 kV) attainable in STEM | |||||||||||
JEOL | JSM-7800F | 1.0nm at 15kV, 0.8nm at 15kV, GB mode | |||||||||||
JEOL | JSM-IC25S | 1970's | [1970s] | ||||||||||
JEOL | JSM-IC845 | 1982/3? | “capable of holding 6 inch semiconductor wafers” [1980s] | ||||||||||
JEOL | JSM-IC848 | 1982/3? | “cold handle 9 inch wafers” [1980s] | ||||||||||
JEOL | JSM IC-848A | 6,000 used 10/05/2013 | |||||||||||
JEOL | JSM-IT300LV | HV: 3nm @ 30kV (SE) LV: 4nm @ 30kV (BSE) | |||||||||||
JEOL | JSM-T20 | 828 | |||||||||||
JEOL | JSM-T200 | 12,000 | |||||||||||
JEOL | JSM-T220 | 1986 | “auto-stigmator and auto-focus” [1980s] | ||||||||||
JEOL | JSM-T330 | 1986 | “auto-stigmator and auto-focus” [1980s] | ||||||||||
JEOL | JSM-T330A | link | |||||||||||
JEOL | JSM-U3 | 50 | 20 | [1960s] | |||||||||
Source | JEOL | JWS-7500E | |||||||||||
JEOL | NeoScope | "10X to 60,000X (printed as a 128mm x 96mm micrograph)" | Benchtop | ||||||||||
JEOL | T-200 | ||||||||||||
JEOL | T-300 | May be able to get manual, contact me | |||||||||||
Leica Cambridge | S 360FE | 5000 | |||||||||||
Leica Cambridge | 260 | 15,000 | |||||||||||
Leica Cambridge | Stereoscan 150u | 1978 | 7 [manual] | 5,000 on craigslist | |||||||||
Leica Cambridge | Stereoscan 240 | 7395 | |||||||||||
Leica Cambridge | Stereoscan 430 | Yes | |||||||||||
Leica Cambridge | Stereoscan 440 | Yes | |||||||||||
Leo | 435VP | 4nm @ 30kV (HV) | |||||||||||
Leo | 1530 | Yes | |||||||||||
Leo | 1550 |