No markings on (damaged) die.
Label:
The back attach was very difficult to get off. It was cooked in WFNA for 30 minutes in an attempt to release it. In retrospect, this was too long of a period and caused the WFNA to dilute, resulting in minor corrosion. It would have been better to do a 24 hour cold soak.
After cooking with no effect, I gave up and was going to try to gently remove it. After only very light handling, chunks started to come out of the back. I immediately stopped trying to remove it and instead went to lightly pick it up to deposit into a vial. The die then fractured from the tweezer pressure.
There appears to be a scratch pre-dating the other damage (given that its corroded). It is unclear where this came from.
The die is quite dirty since I was not able to safely ultrasonic clean it. Now that its been imaged, if there is desire for a cleaner image, I could try to clean it better but it may shatter.