Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
microscope:tech_inst:k2_ind [2014/06/23 14:49] mcmastermicroscope:tech_inst:k2_ind [Unknown date] (current) – removed - external edit (Unknown date) 127.0.0.1
Line 1: Line 1:
-This is a very popular confocal module based on the spinning disc design.  They are designed for either of these two microscopes: 
- 
-    * 012-00010-AA: Leitz Ergolux (infinity optics) 
-    * 012-00010-AB: Nikon IC-66 (210 mm optics) 
- 
-Because it is spinning disc type, you do not need any special electronics and can view the image directly in the eyepiece.  There is a built in sensor that outputs the image to a composite signal at the back BNC connector. 
- 
-Optional "focus finder" attachment evidently does fancy autofocus 
- 
-====== Objectives ====== 
- 
-JM unit doesn't have objectives.  Based on the manual and eBay unit, these are supposed tou se BD Plan 210 mm objectives w/ M26 thread. 
- 
-According to [[http://www.alanwood.net/photography/olympus/microscope-objectives.html|Allanwood Olympus chart]], some objectives that might be compatible are: 
- 
-^ Vendor ^ Series ^ Type ^ Target microscope ^ Threading ^ Notes ^ 
-| Olympus | NeoPlan |  | BH2 | M25 |  | 
-| Olympus | LWDMPlan |  |  | RMS |  | 
-| Olympus | M |  | BH | RMS |  | 
-| Olympus | MNH |  |  | RMS |  | 
-| Olympus | MNM |  |  | RMS |  | 
-| Olympus | MPL |  |  | RMS |  | 
-| Olympus | MPlan |  |  | RMS |  | 
-| Olympus | MPLL |  |  | RMS |  | 
-| Olympus | Neo |  | BH | M25 |  | 
-| Olympus | NeoPlan |  | BH? | M25 |  | 
- 
- 
-====== Nikon ====== 
- 
-System components: 
- 
-^ Image ^ Vendor ^ Part # ^ Type ^ Description ^ Notes ^ 
-| {{microscope:tech_inst:k2_ind:ds_nikon:79.jpg?300}} | Nikon | OPTIPHOT-88 | Microscope | Metallurgical, 210 mm optical path length | Below are subcomponents | 
-| {{microscope:tech_inst:k2_ind:ds_nikon:83.jpg?200}} \\ {{microscope:tech_inst:k2_ind:ds_nikon:85.jpg?300}} | Technical Instruments | 012-00010-AB | Illuminator | Confocal module |  | 
-| {{microscope:tech_inst:k2_ind:ds_nikon:92.jpg?300}} | Nikon | LH-M100CB-1 | Lamphouse |  | Takes mercury or xenon bulbs | 
-|  | Ushio Inc. | USH-102DH | Bulb | "Super-high pressure mercury lamp 100W" | For LH-M100CB-1. [AZ-FL]  | 
-|  | Nikon | ? | Bulb | Xeon | For LH-M100CB-1 | 
-| {{microscope:tech_inst:k2_ind:ds_nikon:82.jpg?200}} | Nikon | HB-10103AF | Power supply | For mercury burner | "FOR 100W SUPER HIGH PRESSURE MERCURY LAMP" | 
-| {{microscope:tech_inst:k2_ind:ds_nikon:87.jpg?300}} | Nikon | BD Plan * | Objective | 210 mm, B/D |  | 
-|  | Nikon | BD PlanAPo * | Objective | 210 mm, B/D, apochromatic |  | 
- 
- 
-===== eBay unit ===== 
- 
-Objectives: 
-  * 1 BD PlanAPo 100/0.90 Nikon Japan 190093 
-  * 1 BD Plan 60/0.80 210/0 Nikon 322933 
-  * 1 BD Plan 20/0.04 210/0 Nikon 421567 
-  * 1 BD Plan 10/0.25 210/0 Nikon 321658 
-  * 1 BD Plan 5/0.1 210/0 Nikon 431584 
- 
- 
-===== Markus Kammerstetter unit teardown (Nikon) ===== 
- 
-Images copyright him, released CC-BY 
- 
-"The lamphouse is of type "lh-m100cb-1". In the unit I have there is a 75W XE arc lamp in the lamp housing" 
- 
-Setup overview: 
- 
-{{:microscope:tech_inst:k2_ind:markus:0.jpg?300}} 
- 
-Internals: 
- 
-{{:microscope:tech_inst:k2_ind:markus:5.jpg?300}}{{:microscope:tech_inst:k2_ind:markus:1.jpg?300}}{{:microscope:tech_inst:k2_ind:markus:2.jpg?300}}{{:microscope:tech_inst:k2_ind:markus:3.jpg?300}}{{:microscope:tech_inst:k2_ind:markus:4.jpg?300}} 
- 
- 
-===== Disposition services (Nikon) ===== 
- 
-Nameplate: 
- 
-<code> 
-Nikon 
-MODEL 
-OPTIPHOT-88 
-AC IN 
-100-120/220-240V 
-3/1.5A 
-50/60Hz 
-JAPAN 
-</code> 
- 
-Overview: 
- 
-{{:microscope:tech_inst:k2_ind:ds_nikon:79.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:81.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:91.jpg?300}} 
- 
-K2 ind confocal module: 
- 
-{{:microscope:tech_inst:k2_ind:ds_nikon:83.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:85.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:86.jpg?300}} 
- 
-K2 rear / lamphouse: 
- 
-{{:microscope:tech_inst:k2_ind:ds_nikon:92.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:93.jpg?300}} 
- 
-Misc: 
- 
-{{:microscope:tech_inst:k2_ind:ds_nikon:87.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:88.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:89.jpg?300}} 
- 
-Lamp PS: 
- 
-{{:microscope:tech_inst:k2_ind:ds_nikon:82.jpg?300}}{{:microscope:tech_inst:k2_ind:ds_nikon:94.jpg?150}} 
- 
-Labels: 
-  MODEL HB-10103AF 
-  Nikon corp. 
-  MADE IN JAPAN 
-   
-  FOR 100W 
-  SUPER HIGH 
-  PRESSURE 
-  MERCURY LAMP 
-   
-  CASE 
-  AC IN 
-  100-120V~ 
-  50/60Hz 3.5A 
-   
- 
- 
-====== Leitz ====== 
- 
-===== Disposition services (Leitz) ===== 
- 
-The Disposition Services units were very nice eand JM tried very hard to get them.  But after a bidding war, everyone needs to have a "walk away" price…sigh :(  They were nice enough to let me take pictures of them anyway though 
- 
-Overview: 
- 
-{{:microscope:tech_inst:k2_ind:ds_leitz:96.jpg?300}} 
-{{:microscope:tech_inst:k2_ind:ds_leitz:97.jpg?300}} 
- 
-K2 ind confocal module:  
- 
-{{:microscope:tech_inst:k2_ind:ds_leitz:98.jpg?300}} 
- 
-Lamphouse: 
- 
-{{:microscope:tech_inst:k2_ind:ds_leitz:99.jpg?300}} 
- 
- 
-====== References ====== 
- 
-    * User manual: http://www.techinst.com/pub_docs/manuals/Industrial/K2 Manual.pdf 
-    * Nikon AZ-FL Epi-Fluoresence Attachment Instructions [AZ-FL]: http://www.mvi-inc.com/wp-content/uploads/AZ-FL-AZ100-Epi-Fl-Attachment.pdf 
- 
  
 
microscope/tech_inst/k2_ind.1403534968.txt.gz · Last modified: 2014/06/23 14:49 by mcmaster
 
Except where otherwise noted, content on this wiki is licensed under the following license: CC Attribution 4.0 International
Recent changes RSS feed Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki