ks:4124 [2018/04/26 05:33] – [PCB] mcmasterks:4124 [2018/04/30 04:53] mcmaster
Line 50: Line 50:
         1 mil wire => 30-30 mils below capillary         1 mil wire => 30-30 mils below capillary
         Greater gap => smaller wire         Greater gap => smaller wire
 +        To adjust: loosen knurled knob
     EFO horizontal     EFO horizontal
         4 mm to left of capillary tip         4 mm to left of capillary tip
         Loosen solenoid clamping screw         Loosen solenoid clamping screw
 +        SHCS allen key: 77 mil
     EFO overtravel     EFO overtravel
         50-60 mil beyond capillary tip         50-60 mil beyond capillary tip
         Loosen solenoid ring set screws         Loosen solenoid ring set screws
 +        SS allen key: 34 mil
 +Capillary adjustment
 +    SHCS allen key: ? couldn't get one to fit. Using pliers to tighten...
 +        diameter: 1.47 mm
 +        thread: 1.25 / 4 = 0.3125 mm
 +    Capillary diameter: 1/16"
 +    Allen key inserted for alignment: 56 mil
 +        63 mil diagonol vs 1/16" => 63 mil
 Wire loading Wire loading
     6.1.10     6.1.10
     First o-ring 3/8" from flared side of funnel     First o-ring 3/8" from flared side of funnel
 </code> </code>
 +
 +150C workholder
  
 ====== Connectors ====== ====== Connectors ======
 
 