Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
decap:epoxy [2018/02/28 02:43] – [CLC ControlLaser FALIT] mcmasterdecap:epoxy [2019/05/13 21:00] – [Light Ray] mcmaster
Line 149: Line 149:
   * Practice on samples before trying something you care about   * Practice on samples before trying something you care about
   * Puts off nasty fumes. Make sure to have good ventilation   * Puts off nasty fumes. Make sure to have good ventilation
 +
 +From Sam Wagner:
 +  * "We use a yterrbium fiberlaser. What you are doing is trying to cause the plastic compound to explosively eject the silicon beads. So a pulsed laser is critical.  The laser melts the plastic and the pulse hopefully causes it to vaporize and eject beads."
 +  * "Important to note that if you see silicon, you’ve destroyed the chip and can now no longer do FA work. We stop at the bond wires and use acid or plasma to remove the rest. Then it’s off to SEM or TIVA/LIVA or whatever you’re next step is."
 +
  
 ===== jamiecraig ===== ===== jamiecraig =====
Line 217: Line 222:
   * They do the whole chip but avoid die area   * They do the whole chip but avoid die area
   * Light Ray - IC Decapsulation   * Light Ray - IC Decapsulation
 +
 +
 +===== mcmaster ezlaze =====
 +
 +TODO: add pictures, estimate material removal rate
 +
 +Basically this was too slow to be practical except for very small samples. That said, it did work very well. A quicklase or other higher throughput Nd:YAG system would likely work well
  
 ====== Sandblast ====== ====== Sandblast ======
Line 292: Line 304:
  
  
-====== A. Zonenberg etch rate measurement ====== 
- 
-FIXME: move this somewhere better 
- 
-Copper etch - 70 ml 3% H2O2 + 10 ml conc. HCl. Heat to 70C, agitate with magnetic stirrer. 
- 
-Test sample was Altera Stratix IV. Silver or tin plated copper. Plating was gone after <1 min in etchant, metallurgy of the plating was not studied. 20 minutes of etching = 0.13mm removal so 6.5 um/min. This number is likely +/- 30% or so because the temperature of the solution slowly increased over the etch period. 
  
 ====== References ======  ====== References ====== 
 
decap/epoxy.txt · Last modified: 2023/09/04 07:42 by mcmaster
 
Except where otherwise noted, content on this wiki is licensed under the following license: CC Attribution 4.0 International
Recent changes RSS feed Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki