| + | See also: http:// | ||
| + | |||
| Since microscopes are a critical instrument this section provides information on both microscope techniques and equipment. | Since microscopes are a critical instrument this section provides information on both microscope techniques and equipment. | ||
| + | |||
| + | [[: | ||
| ====== General reccomendations (optical) ====== | ====== General reccomendations (optical) ====== | ||
| Line 58: | Line 62: | ||
| My standard system is something like: | My standard system is something like: | ||
| * Olympus BH2 core w/ BH2-UMA | * Olympus BH2 core w/ BH2-UMA | ||
| + | * Chassis | ||
| + | * Don't have a consistent option here | ||
| + | * Post mounted (ex: BH2 BHMJ) is easy to use | ||
| + | * The large frame used on prawnscope is relatively popular, but I don't know model number | ||
| * Surplus linear stages | * Surplus linear stages | ||
| * Retrofitted with MDrive17 integrated driver stepper motors | * Retrofitted with MDrive17 integrated driver stepper motors | ||
| * Machined mounts | * Machined mounts | ||
| - | * Newport mirror | + | * Mirror |
| + | * Full size: large mount (ex: Newport NRC 39) rightside up | ||
| + | * Small / low cost: small mount (ex: Newport MM2) upside down | ||
| * Machinekit on beagle bone black (BBB) as CNC controller | * Machinekit on beagle bone black (BBB) as CNC controller | ||
| - | * Usually with an Adafruit 572: Proto Cape Kit for BeagleBone & Beagle Bone Black | + | * Usually with an Adafruit 572 (Proto Cape Kit for BeagleBone & Beagle Bone Black) for connectors and/or level translation |
| * Thinkpad T61p controlling the microscope | * Thinkpad T61p controlling the microscope | ||
| * MU800 microscope camera | * MU800 microscope camera | ||
| * Modified v4l Linux driver for the MU800 | * Modified v4l Linux driver for the MU800 | ||
| * For direct RGB control | * For direct RGB control | ||
| - | * pr0ntools | + | * prawntools |
| - | [[https://siliconpr0n.org/ | + | [[https://siliconprawn.org/ |
| Line 108: | Line 118: | ||
| Follow the [[http:// | Follow the [[http:// | ||
| - | ====== Field Stop (FS) and Aperature Stop (FS) ====== | ||
| - | |||
| - | Properly adjusted can give a real improvement in image quality. | ||
| - | |||
| - | {{: | ||
| - | |||
| - | Adjusted (Mit20x objejective): | ||
| - | |||
| - | {{: | ||
| - | |||
| - | |||
| - | ====== DIY non-optical ====== | ||
| - | |||
| - | * [[http:// | ||
| - | * [[http:// | ||
| - | * http:// | ||