Both sides previous revisionPrevious revision | |
microscope:sem:i-o [2015/03/12 04:43] – mcmaster | microscope:sem:i-o [Unknown date] (current) – removed - external edit (Unknown date) 127.0.0.1 |
---|
^Image ^Vendor ^Model ^Year ^kV ^Gun ^Resolution (nm) ^Features ^List price ^Manual ^Schem ^SW ^Notes | | |
| |ISI |Alpha 9 | | | | | |June 1980: L10,790 | | | |Referenced in price sheet | | |
|{{:umt:isi:cl-6:analytical_top.jpg?300}} \\ Source: [UMT EA] |ISI |CL-6 | | | | | | | | | | | | |
|{{:ds130:isi:ds130:ds-130.jpg?300}} \\ Source: [DS130 DS130] |ISI |DS 130 | |40 | | \\ 3 (top stage) \\ \\ 6 (bot stage) | | \\ Oct 1981: \\ \\ /1: L43,995 \\ \\ /2: L49,245 \\ \\ /3: L51,975 \\ \\ L49,990 [June 1980 prices] | | | | \\ DS 130/1: Bottom Stage only \\ \\ DS 130/2: Top Stage only \\ \\ DS 130/3: Complete Top and Bottom Stage System | | |
| {{:isi:dtradingpost:isi-40:isisemfull.jpg?300}} \\ Source: [dtradingpost ISI-40] | ISI | \\ ISI-40 \\ \\ SMS-2D | | | | | |L22,390 [June 1980 prices] | | | |TODO: index schematic list | | |
| |ISI |ISI-60 |1979 | | | | |<$30,000 \\ \\ (1979) [isi research advert] | | | |Advert lists it as new the same time as the Super IIIA and I know the Super IIIA was around 1979 | | |
| |ISI |ISI-60A | | | | | |L26,990 [June 1980 prices] | | | | | | |
| |ISI |ISI-100 |1977 |25? |LAB<sub>6</sub> |10? | | | | | |"could handle 4-inch-diameter specimens" [1970s] | | |
| |ISI |ISI-100N | | | | | |L35,890 [June 1980 prices] | | | | | | |
|{{:ams:isi:ss60:img_1264.jpg?300}} \\ Source: [AMS SEM] |ISI |ISI-SS60 | | | | | | | | | | | | |
|{{:mcmaster:isi:m-7:m7front.jpg?300}} \\ {{:mcmaster:isi:m-7:isicolumn.jpg?300}} \\ Source: private e-mail |ISI |[[:microscope:sem:isi:m-7|M-7]] | | | | | | | | | |Very hard to find info on this unit | | |
|{{:osu:isi_msm-2_mini_sem.jpg?300}} \\ Source: [OSU MINISEM1] |ISI |MSM-2 |1973 | | |[[http://www.science.oregonstate.edu/emfacility/?q=node/History/EM/MINISEM1|30]] | |$17,000 | | | | \\ Tabletop \\ \\ [OSU MINISEM1] | | |
| |ISI | \\ [[:microscope:sem:isi:sms|SMS-1]] \\ \\ [[:microscope:sem:isi:sms|Super-Mini-SEM 1]] | 1974 | 25 | |10 | | | |[[:microscope:sem:isi:sms|Yes]] | |"could accommodate samples up to 32 mm in diameter" [1970s] | | |
| |ISI | \\ [[:microscope:sem:isi:sms|SMS-2]] \\ \\ [[:microscope:sem:isi:sms|Super-Mini-SEM 2]] | 1975 | 25? | |10? | | | |[[:microscope:sem:isi:sms|Yes]] | | \\ "increased the sample chamber size to 3 inches in diameter"[1970s] \\ \\ JM may have partial or full schematic | | |
|{{:mcmaster:isi:super_iiia:01.jpg?300}} |ISI | \\ SMS-3A \\ \\ Super-Mini-SEM III \\ "[[:microscope:sem:isi:super_iii_a|Super III A]] " | ~1980 | 30 | WHP | 7 | | \\ \\ <$30,000 \\ \\ (1979) [isi research advert] \\ \\ L15,800 [June 1980 prices] | \\ [[http://siliconpr0n.org/media/isi/super_iiia/manual/isi_siii-a_k_instruction_manual_kc.pdf|Yes]] ([[http://siliconpr0n.org/media/isi/super_iiia/manual/isi_siii-a_k_instruction_manual_bl.pdf|alt]]) \\ \\ [[http://siliconpr0n.org/media/isi/super_iiia/manual/|All]] | [[:microscope:sem:isi:sms|Yes]] | | \\ [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope.html|ref]] | | |
|{{:isi:ptli:isi-ss40:sem_3.jpg?300}} \\ Source: [PTLI ISI-SS40] |ISI |SS-40 | | | | | | |[[http://siliconpr0n.org/media/isi/ss-60/isi_ss-60_instruction_manual.pdf|Partial?]] | | | | | |
|{{:jean_drohe:isi:ss-60:isi_ss-60.jpg?300}} \\ Source: Jean Drohé private communication |ISI | SS-60 | | | | | | |[[http://siliconpr0n.org/media/isi/ss-60/isi_ss-60_instruction_manual.pdf|Yes]] | | | | | |
| |ISI | SS-130 | | | | | | |[[http://siliconpr0n.org/media/isi/ss-60/isi_ss-60_instruction_manual.pdf|Partial?]] | | | | | |
|{{:tntech:isi:sr50:image016.jpg?300}} \\ Source: [TNTech MSE] |ISI |SR50 | | | | | | | | | | | | |
| {{:virago:isi:sx30:at_school_a.jpg?300}} \\ Source: [Virago] |ISI | SX30 | | | | | | | | | | [Virago] | | |
| |ISI | SX-30/E4 | |5, 15, 25 | |7 | | | | | | See advert | | |
|{{:equipmatching.com:isi:sx-40:1.jpg?300}} \\ Source: [equipmatching] |ISI | SX-40 | | | \\ 30 | 6 | | |[[http://siliconpr0n.org/media/isi/sx-40/isi_sx-40_instruction_manual.pdf|Yes]] | | | \\ Thanks to Nathalie Renevier for the user manual! \\ \\ Specifications on page 67 | | |
| |ISI | SX-60 | | | | | | | | | |Mentioned on ds130 website but I can't find any other references to this model | | |
| |ISI | SYSTEM-100A | | | | | | | | | | | | |
|{{:mcmaster:isi:tv_mini_sem:nb_overview.jpg?200}} |ISI | \\ TV Mini-SEM \\ ([[:microscope:sem:isi:msm|TV-MSM]]) \\ \\ Schematic: MRS-2 | 1976 | | | | | | |[[http://siliconpr0n.org/media/isi/tv-msm/schem/|Yes]] | | \\ [[https://www.noisebridge.net/wiki/SEM|Noisebridge unit]] \\ \\ Year based off of schematic date | | |
| {{:ebay:product4you80:isi:wb-6:0.jpg?300}} \\ Source: [eBay 231289327125] | ISI | WB-6 | | | | | | | | | | | | |
| |JEOL |ClairScope JASM-6200 | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/AtmosphericSEM/ClairScope%E2%A2JASM6200/tabid/727/Default.aspx#216960-specifications|W/8nm (30kV)]] | | | | | |Atmospheric | | |
| |JEOL |JAMP-10 | | | | | | | | | | | | |
| |JEOL |JIB-4500 | | | | | | | | | |Multibeam FIB | | |
| |JEOL |JIB-4600F | | | | | | | | | |Multibeam FIB | | |
| |JEOL |JEM-100S | | | | | |Ask: [[http://www.ebay.com/itm/Jeol-Jem-100S-Electron-Microscope-/330904701981?pt=LH_DefaultDomain_0&hash=item4d0b750c1d|14999]] [[http://www.ebay.com/itm/Jeol-JEM-100S-Electron-Microscope-/300892292497?pt=LH_DefaultDomain_0&hash=item460e940591| 20,000]] | | | |[1960s] | | |
| |JEOL |JEM-ARM-1000 |1983 |1000 | | | | | | | |"one-of-a-kind Ultrahigh Voltage EM for the Lawrence Berkeley Laboratories in California, where scientists were interested in atomic resolution" [1980s] | | |
| |JEOL |JFSM-30 |1974 | |FE |3 | | | | | |[1970s] | | |
| |JEOL |JRSM-50A |1973 | | | | | | | | |"hot stage for examining samples at elevated temperatures" [1970s] | | |
| |JEOL |JSM-1 | |50 | |50 | | | | | |[1960s] | | |
| |JEOL |JSM-2 | |50 | | | | | | | |[1960s] | | |
| |JEOL |JSM-U | |50 | | | | | | | |[1960s] | | |
| |JEOL |JSM-35CF | | | | | |Ask: [[http://www.ebay.com/itm/Jeol-JSM-35CF-Scanning-Electron-Microscope-SEM-XRF-Micro-X-Ray-spectrometer-XRF-/181219143767?pt=LH_DefaultDomain_0&|4,900 used 10/05/2013]] | | | | | | |
| |JEOL |JSM-35CFS |1982/3? | | | | | | | | |[1980s] | | |
| |JEOL |JSM-820 | | | | | | | | | | | | |
| |JEOL |JSM-840 |1982/3? | | |[[http://www.microscopy.ou.edu/jsm-840.shtml|3]] | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-840-Scanning-Electron-Microscope-Condition-unknown-Parts-or-fun-/300750575613?pt=LH_DefaultDomain_0&hash=item46062197fd|3900]] | | | | \\ "best i've gotten out of it was resolving ~60nm colloidal silica particles" [az] \\ \\ year: [1980s] | | |
| |JEOL |JSM-5200 | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-5200-SEM-Scanning-Electron-Microscope-Nice-/310706225626?pt=LH_DefaultDomain_0&hash=item485788c1da|18950]] | | | | | | |
| |JEOL |JSM-5400 | | | | | | | | | | | | |
| |JEOL |JSM-5800 | | | | | | | | | | | | |
| |JEOL |JSM-5900 | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-SEM-JSM-5900-Scanning-Electron-Microscope-Turbo-Racker-Molecular-Pump-NICE-/261241434194?pt=LH_DefaultDomain_0&hash=item3cd333f052|6000]] | | | | | | |
|{{:kitmondo:jeol:jsm-5900lv:jsm-5900lv.jpg?300}} \\ [[http://www.kitmondo.com/jeol-jsm-5900lv/ref242818|Source]] |JEOL |JSM-5900LV | | | |3nm @ 30kV (SEI) \\ 5nm @30kV (BEI) | | | | | | | | |
| |JEOL |JSM-5910 | | | | | | | | | | | | |
| |JEOL |JSM-6010LA | | | | \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|HV: 4nm @ 20kV (SE)]] \\ \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|LV: 5nm @ 20kV (BSE)]] | | | | | | | | |
| |JEOL |JSM-6010PLUS \\ "JSM-6010PLUS InTouchScope" | | | | | | | | | | | | |
| |JEOL |JSM-6100 | | | | | |Ask: [[http://www.ebay.com/itm/Jeol-JSM-6100-Scanning-Electron-Microscope-SEM-Imaging-demo-Video-/321220953743?pt=LH_DefaultDomain_0&hash=item4aca42c68f|10,000]] | | | | | | |
| |JEOL |JSM-6300F | | |CFE |1.5 nm @ 30 kV | | | | | | | | |
| |JEOL |JSM-6300LV | | | | | | | | | | | | |
| |JEOL |JSM-6300V | | | | | |Ask: [[http://www.ebay.com/itm/Jeol-JSM-6300V-Electron-Scanning-Microscope-/121063235744?pt=LH_DefaultDomain_0&hash=item1c2fee60a0|9500]] | | | | | | |
| |JEOL |JSM-6340F | | |CFE |2.5 nm @ 1 kV \\ 1.2 nm @ 20 kV | | | | | | | | |
| |JEOL |JSM-6390 | | | | | | | | | | | | |
| |JEOL |JSM-6390LV | | | | | | | | | | | | |
| |JEOL |JSM-6400 | | | | | | \\ Ask: [[http://www.ebay.com/itm/JEOL-6400-SCANNING-ELECTRON-MICROSCOPE-/281127472961?pt=LH_DefaultDomain_0&hash=item417480cf41|10,000]] \\ \\ Ask: [[http://www.ebay.com/itm/JEOL-JSM-6400-F-SEM-scanning-electron-microscope-/400170674525?pt=LH_DefaultDomain_0&hash=item5d2c07e95d|11,000]] | | | | | | |
|{{:kitmondo:jeol:jsm-6460:jeol_6460_sem.jpg?300}} \\ [[http://www.kitmondo.com/jeol-jsm-6460-with-oxford-inca-energy-eds/ref69259|Source]] |JEOL |JSM-6460 |~2004 | | | | | | | | | | | |
| |JEOL |JSM-6510 | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|LV: 3nm @ 30kV (SE)]] | | | | | | | | |
| |JEOL |JSM-6510LV | | | | \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|HV: 3nm @ 30kV (SE)]] \\ \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|LV: 4nm @ 30kV (BSE)]] | | | | | | | | |
| |JEOL |JSM-7100F | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/FESEM/JSM7100F/tabid/865/Default.aspx|1.2nm at 30kV]] | | | | | | | | |
| |JEOL |JSM-7500F | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/FESEM/JSM7500F/tabid/394/Default.aspx|x 25 to 1,000,000 (printed as a 120mm x 90mm micrograph)]] | | | | | | | | |
| |JEOL |JSM-7610F | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/FESEM/JSM7610F/tabid/544/Default.aspx#199137-specifications|1.0 nm (15 kV), 0.6 nm (30 kV) attainable in STEM]] | | | | | | | | |
| |JEOL |JSM-7800F | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/FESEM/JSM7800F/tabid/869/Default.aspx|1.0nm at 15kV, 0.8nm at 15kV, GB mode]] | | | | | | | | |
| |JEOL |JSM-IC25S |1970's | | | | | | | | |[1970s] | | |
| |JEOL |JSM-IC845 |1982/3? | | | | | | | | |"capable of holding 6 inch semiconductor wafers" [1980s] | | |
| |JEOL |JSM-IC848 |1982/3? | | | | | | | | |"cold handle 9 inch wafers" [1980s] | | |
| |JEOL |JSM IC-848A | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-IC-848A-Scanning-Electron-Microscope-with-Thermo-Noran-EDS-/130973712504?pt=LH_DefaultDomain_0&hash=item1e7ea44078|6,000 used 10/05/2013]] | | | | | | |
| |JEOL |JSM-IT300LV | | | | \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|HV: 3nm @ 30kV (SE)]] \\ \\ [[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/HighVacuumLowVacuum/tabid/186/Default.aspx|LV: 4nm @ 30kV (BSE)]] | | | | | | | | |
| |JEOL |JSM-T20 | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-T20-SCANNING-ELECTRON-MICROSCOPE-1ST-GEN-57318-/300934632704?pt=BI_Control_Systems_PLCs&hash=item46111a1500|828]] | | | | | | |
| |JEOL |JSM-T200 | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-T200-Scanning-Electron-Microscope-With-Fuly-Operational-EDS-and-Chiller-/360679937251?pt=LH_DefaultDomain_0&hash=item53fa3314e3|12,000]] | | | | | | |
| |JEOL |JSM-T220 |1986 | | | | | | | | |"auto-stigmator and auto-focus" [1980s] | | |
| |JEOL |JSM-T330 |1986 | | | | | | | | |"auto-stigmator and auto-focus" [1980s] | | |
| |JEOL |JSM-T330A | | | | | |Ask: [[http://www.ebay.com/itm/JEOL-JSM-T330A-ELECTRON-SCANNING-MICROSCOPE-AND-CONTROL-CENTER-S-N-MP-168121-3-/290714985190?pt=LH_DefaultDomain_0&hash=item43aff6a2e6|link]] | | | | | | |
| |JEOL |JSM-U3 | |50 | |20 | | | | | |[1960s] | | |
|{{:kitmondo:jeol:jws-7500e:ab4faf27-fcce-452d-88e9-fdd7658c4204.jpg?300}} \\ [[http://www.kitmondo.com/jeol-jws7500e/ref449407|Source]] |JEOL |JWS-7500E | | | | | | | | | | | | |
| |JEOL |NeoScope | | | |[[http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopes(SEM)/Benchtop/NeoScopeBenchtopSEM/tabid/870/Default.aspx|"10X to 60,000X (printed as a 128mm x 96mm micrograph)"]] | | | | | |Benchtop | | |
| |JEOL |T-200 | | | | | | | | | | | | |
| |JEOL |T-300 | | | | | | | | | |May be able to get manual, contact me | | |
| |Leica Cambridge |S 360FE | | | | | |Ask: [[http://www.ebay.com/itm/Leica-Cambridge-Instruments-S-360FE-SEM-Scanning-Electron-Microscope-Camscan-/180992856106?pt=LH_DefaultDomain_0&hash=item2a2403d02a|5000]] | | | | | | |
| |Leica Cambridge |260 | | | | | |Ask: [[http://www.ebay.com/itm/CAMBRIDGE-INSTRUMENTS-STEREO-SCAN-260-SCANNING-ELECTRON-MICROSCOPE-W-OXFORD-EDS-/290750338459?pt=LH_DefaultDomain_0&hash=item43b212159b|15,000]] | | | | | | |
| |Leica Cambridge |Stereoscan 150u |1978 | | |7 [manual] | |Ask: 5,000 on craigslist | | | | | | |
| |Leica Cambridge |Stereoscan 240 | | | | | |Ask: [[http://www.ebay.com/itm/Cambridge-Instruments-Stereo-Scan-Model-240-Scanning-Electron-Microscope-System-/300948700632?pt=LH_DefaultDomain_0&hash=item4611f0bdd8|7395]] | | | | | | |
| |Leica Cambridge |Stereoscan 430 | | | | | | |[[http://siliconpr0n.org/media/leica_cambridge/stereoscan_430/operator_manual/|Yes]] | | | | | |
| |Leica Cambridge |Stereoscan 440 | | | | | | |[[http://siliconpr0n.org/media/leica_cambridge/stereoscan_440/stereoscan_440.pdf|Yes]] | | | | | |
| |Leo |435VP | | | |4nm @ 30kV (HV) | | | | | | | | |
| |Leo |1530 | | | | | | |[[http://siliconpr0n.org/media/leo/1530/20100929044721481.pdf|Yes]] | | | | | |
| |Leo |1550 | | | | | | | | | | | | |
| |
\\ | |
| |