-The third Super-Mini-SEM, ISI marketing shortened it to simply Super IIIA.  However, the schematics still refer to it as the SMS-IIIA. 
- 
-See [[:microscope:sem:isi:sms|SMS]] family page for schematics 
- 
-JM has one 
- 
-"SIII-A(K) (1976)" 
- 
- 
-====== Filament ====== 
- 
-Good overview of SEM filament types: http://www.reu.pdx.edu/SEM%20Short%20Course.pdf 
- 
-Trying to find replacement filaments.  Takes the ISI three prong type 
- 
-Prices as of 04/21/2014 
- 
-^Vendor ^Item # ^Description ^Price/pack ^Qty/pack ^Qty/each ^Notes | 
-|Ted Pella |[[https://www.tedpella.com/apertures-and-filaments_html/tungsten-filaments.htm|1426]] |ISI / ABT / Topcon 3-pin |425.00 |10 |42.50 |  | 
-|Electron Microscopy Sciences |[[http://www.emsdiasum.com/microscopy/products/microscope/filament.aspx|81038]] |   \\ STANDARD LOOP FILAMENTS for: ISI Instruments, ABT, Topcon      \\   \\ New Filament, 3-prong  |  416.00 |  10 |  41.60 |  | 
-|Electron Microscopy Sciences |[[http://www.emsdiasum.com/microscopy/products/microscope/filament.aspx|81038-R ]] |   \\ STANDARD LOOP FILAMENTS for: ISI Instruments, ABT, Topcon      \\   \\ Rebuilt Filament, 3-prong  |  |  1 |  32.00 |  | 
-|SPI Supplies |[[http://www.2spi.com/catalog/filaments/fil1.shtml|5232N-BA]] |Topcon/ISI 3-pin |525.49 |10 |52.55 |  | 
-|SPI Supplies |[[http://www.2spi.com/catalog/filaments/fil1.shtml|5232RB-AB]] |Topcon/ISI 3-pin (rebuilt) |  |1 |41.57 |  | 
-|EB Sciences |[[http://www.ebsstore.com/product.aspx?pid=354|ISIE]] |Standard loop, 3 Prong |405.00 |10 |40.50 |  | 
-|EB Sciences |[[http://www.ebsstore.com/product.aspx?pid=354|ISIE]] |AR loop, 3 Prong |455.00 |10 |45.50 |  | 
-|Fisher Scientific |[[http://www.fishersci.com/ecomm/servlet/itemdetail?itemdetail='item'&storeId=10652&productId=14218960&catalogId=29104&matchedCatNo=5029087&fromSearch=1&searchKey=3-prong&highlightProductsItemsFlag=Y&endecaSearchQuery=#store=Scientific#nav=0#rpp=25#offSet=25#keyWord=3-prong#searchType=PROD#SWKeyList=[]&xrefPartType=From&savings=0.0&xrefEvent=1398144201666_2&searchType=PROD&hasPromo=0|50-290-87]] |NEW FILAMENT 3-PRONG |509.60 |10 |50.96 |  | 
-|Soquelec |[[http://www.soquelec.ca/filaments4-5.asp|A20135]] |ISI (2-prong, new) |  |1 |68.10 |NOTE: 2 prong for comparison | 
-|Soquelec |[[http://www.soquelec.ca/filaments4-5.asp|A20140]] |ISI (2-prong, rebuilt) |  |1 |39.00 |NOTE: 2 prong for comparison | 
-|ME Taylor |[[http://www.semicro.org/topconisi3-pinstylefilaments-packageof10.aspx|F-3]] |Topcon/ISI 3-pin style Filaments - Package of 10 |275.00 |10 |27.50 |  | 
- 
-===== EB Sciences ===== 
- 
-Has several filament types 
- 
-==== Type AR ==== 
- 
-"The Energy Beam Sciences exclusive AR tip represents the state of art in filament technology. This special loop was developed for applications which demand the ultimate in mechanical stability and operating life. It is particularly recommended for use in multi-user environments and teaching laboratories. Its etched taper loop configuration and unique tip geometry enhance contrast and brightness, even at low kV. We can provide the AR loop mounted on any type of filament base. Whatever your application, you should see enhanced performance with the AR loop, when compared with the standard loop filament supplied by the EM equipment manufacturer." 
- 
-==== Standard Loop ==== 
- 
-"Energy Beam Sciences Standard Loop Tungsten Filaments are designed to conform to Original Equipment Manufacturers' specifications across the industry.  Our filaments are individually manufactured with careful attention to detail, maintaining  their precise tip geometry and using superior assembly techniques and stringent quality control for consistency and dependability in even the most demanding applications.  At Energy Beam Sciences, we offer cost effective, reliable solutions for these and all of your EM consumable needs.  Please call our e-Beam product specialist today to find out more about our quality products!" 
- 
- 
-====== JM electron gun ====== 
- 
-Original unit that SEM came with. 
- 
-XXX: supposedly this SEM takes a "three prong filament" and in fact has a three contact base.  What is difference between the two types? 
- 
-Wehnelt assembly: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:apart1.jpg?300}} 
- 
-Base it plugs into: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:base.jpg?300}} 
- 
-Taking off top retainer: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:apart2.jpg?300}} 
- 
-Removing the Wehnelt: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:apart3.jpg?300}} 
- 
-Note that the filament is slightly twisted to form the tip.  Also, its burned out 
- 
-Wehnelt bottom: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:topbot.jpg?300}} 
- 
-Side of the filament assembly 
- 
-{{:microscope:sem:isi:super_iii_a:gun:side1.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:gun:side2.jpg?300}} 
- 
-Filament tip: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:tip.jpg?300}} 
- 
-Everything together: 
- 
-{{:microscope:sem:isi:super_iii_a:gun:apart.jpg?600}} 
- 
- 
-====== lapointe2 ====== 
- 
-[[http://members.tm.net/lapointe2/scanning_electron_microscope.html|http://members.tm.net/lapointe2/scanning_electron_microscope.html]] 
- 
-Great resource on this model.  Unfortunately, links to pages are hidden throughout the text so I've tried to index it a bit better.  I also have mirrored the site in case it disappears: 
- 
-    * [[http://members.tm.net/lapointe2/scanning_electron_microscope.html|Home]] 
-    *  [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Operation.html|Operation]] 
-      * Like a user manual: read it 
-    * [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Vacuum.html|High vacuum system]] 
-    * [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_HVPS.html|High voltage power supply]] 
-    * [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Vibration.html|Anti-vibration mounts]] 
-    *  [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Cooler.html|DP cooler]] 
-      * DIY chiller 
-    * [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Filament.html|Changing the filament]] 
-    * [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Scintillator.html|Changing the scintillator]] 
- 
-These are less about the SEM and more about his particular logistics: 
- 
-    *  [[http://members.tm.net/lapointe/Vacuum_Pump.html|Vacuum pump and gauge]] 
-      * Hooking up his roughing pump 
-    *  [[http://members.tm.net/lapointe2/Scanning_Electron_Microscope_Plug_In.html|Plug it in]] 
-      * Hooking up his electrical lines 
- 
-===== Cleaning ===== 
- 
-Wenol metal polish recommended for cleaning.  MSDS lists 
- 
-    * Ammonia Solution 25%: 1-5% 
-    * Kerosene 200-230: 10-20% 
-    * White Spirit 150/200N: 10-20% 
-    * Aluminum oxide (pigments): 25-35% 
-    * Coco fatty acid diethanolamide: 5-15% 
-    * Water: 35% 
- 
-[[https://www.tedpella.com/material_html/polish.htm#Anchor-47857|https://www.tedpella.com/material_html/polish.htm#Anchor-47857]] 
- 
-    * "Wenol® is widely used as cleaner and polish for electron microscope applications, ion beam systems, vacuum coating systems and general lab applications. Wenol® has been originally formulated for use on hard metal surfaces such as stainless steel. It can be used to clean and polish hard metal parts for vacuum systems. The carrier fluid dissolves in most hydrocarbons and is easily removed. Wenol® is petroleum based and does not contain silicones. It is not recommended for use on soft metal such as aluminum." 
- 
-Ted Pella also has Unipol…not sure when to use one vs the other.  Generic Wenol? 
- 
-    * Aluminium oxide: 20-40 
-    * Ammonia solution: 0.1-5 
-    * Destillates (petroleum), hydrotreated light: 20-40 
-    * Naphtha (petroleum), hydrotreated light: 2.5-10 
- 
-read somewhere 100ml ~= 3.4oz Wenol 
- 
-====== o-rings ====== 
- 
-Drawings in this section are from Lapointe's website 
- 
-may consider replacing o-rings as the vacuum is sub-par.  By the time I disassemble everything might as well replace them 
- 
-"o-rings are labeled with their aerospace standard AS568A size" 
- 
-===== High vacuum assembly ===== 
- 
-{{:microscope:sem:isi:super_iii_a:sem_vacuum_drawing.gif}} 
- 
-Abbreviations: 
- 
-    * ID: inner diameter 
-    * OD: outer diameter 
-    * CS: cross section 
- 
-What is difference between nominal and actual size? 
- 
-^AS568A size ^ID ^OD ^CS ^Qty | 
-|011 |1 |  |  |  | 
-|013 |1 |  |  |  | 
-|118 |2 |  |  |  | 
-|128 |1 |  |  |  | 
-|141 |1 |  |  |  | 
-|214 |1 |  |  |  | 
-|215 |2 |  |  |  | 
-|216 |1 |  |  |  | 
-|220 |2 |  |  |  | 
-|221 |1 |  |  |  | 
-|222 |2 |  |  |  | 
-|226 |1 |  |  |  | 
-|233 |1 |  |  |  | 
- 
-===== Valve assembly ===== 
- 
-{{:microscope:sem:isi:super_iii_a:sem_asbvalve_drawing.gif}} 
- 
-^AS568A size ^Qty | 
-|006 |1 | 
-|121 |2 | 
-|123 |1 | 
- 
-====== uccs.edu PES415 ====== 
- 
-Has a sort of instruction manual: [[http://www.uccs.edu/~tchriste/courses/PES415/SEM.pdf|http://www.uccs.edu/~tchriste/courses/PES415/SEM.pdf]] 
- 
-====== Units for sale with pictures ====== 
- 
-EAMTM: [[http://www.machinedeal.com/en/profileprojectors-and-measuring-microscope/super-iii-a-111957/|http://www.machinedeal.com/en/profileprojectors-and-measuring-microscope/super-iii-a-111957/]] 
- 
-buckeye43701: [[http://www.ebay.com/itm/Scanning-Electron-Microscope-ISI-Model-Super-III-A-/321271545594?nma=true&si=OVGlVAabuHwcYtHSq03p071SPjE=&orig_cvip=true&rt=nc&_trksid=p2047675.l2557|http://www.ebay.com/itm/Scanning-Electron-Microscope-ISI-Model-Super-III-A-/321271545594?nma=true&si=OVGlVAabuHwcYtHSq03p071SPjE=&orig_cvip=true&rt=nc&_trksid=p2047675.l2557]] 
- 
-\\ 
- 
- 
-====== EDAX ====== 
- 
-The extra vacuum ports are likely intended for EDAX and in fact I did find one such unit. 
- 
- 
-===== govdeals ===== 
- 
-All images in this section are from [[http://www.govdeals.com/index.cfm?fa=Main.Item&itemid=8058&acctid=685|GovDeals]] 
- 
-"You will be bidding on a International Scientific Instruments Model Super III A Scanning Electron Microscope. The unit was purchased in 1979 and converted to digital and updated in 1999. This unit comes with a Robinson Backscatter detector, Gresham Titan X-ray pulse-processor, 4PI digital imaging attachment, control computer and software. The agency is reporting the unit is operational except for the X-ray detector analyzer and the software is up to date (uses Macintosh OS9). There are miscellaneous spare parts, filament assemblies, a manual, schematics and a TMC anti-vibration platform is included...located on the Winthrop University Campus in Rock Hill, South Carolina." 
- 
-This is by far the most pimped out unit I've found so far: 
-  * Computer image capture 
-  * Maybe computer control? 
-  * Robinson Backscatter detector (is that the special PMT assembly?) 
-  * Gresham Titan X-ray pulse-processor (for the EDS?) 
- 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_10.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_2.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_3.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_4.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_5.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_7.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_8.jpg?300}} 
-{{:microscope:sem:isi:super_iii_a:govdeals:685_8058_9.jpg?300}} 
- 
-====== References ====== 
- 
-  * Original schematic scan: http://siliconpr0n.org/uv/super_iiia/schem_raw/ 
-  * User manual: http://siliconpr0n.org/uv/super_iiia/manual/ 
-  * JM blog posts 
-    * http://uvicrec.blogspot.com/2014/04/a-new-toy-arrives.html 
-    * http://uvicrec.blogspot.com/2014/06/rolling-with-sem.html 
- 
- 
- 
  
 