This is an old revision of the document!


FIXME: this page is a few things merged together. It was cleaned up after the intruded.net crash and so needs to be re-cleaned up

This page describes various chemical solutions applied to ICs for various effects. Primary reasons:

The etchant is sometimes called a corrodent. Miller indices (eg: {111}) are used to denote crystal properties. Many of these solutions have strong temperature dependencies.

Some solutions are used for more than one purpose. They are in the area most associated with them or at least of the most use on this site.

Open questions

When I etch chips far down with HF some sort of crud builds up. What is it? Can it be prevented? Can it be removed? TODO: add picture

General notes

Hydrofluoric acid (HF)

Many of the solutions on this page involve this chemical. It is extremely dangerous and should only be handled if you know what you are doing. See site disclaimer on main page. If solution is sufficient concentration you will die a horrible death if it spills on you. That said, < 3.0% or so solutions are sold over the counter to consumers in the US as certain types of rust removers (ie one would hope its reasonably safe). The same solutions are banned for over the counter sales in the EU.

HF eats glass. Avoid using glass containers as they will get eaten and influence the etchant concentration, making etching less predictable. Polypropylene (PP), fluoropolymers (PTFE, PFA, FEP, ETFE, etc), and HDPE are all HF and acetone resistant. Of these PTFE and PP are the best. See corrosion data here and here.

Importance of cleaning

Dies must be clean before etching. If they are dirty (ex: oil patch) the etching will be very uneven. Above: SiO2 skeleton leftover from contaminated areas blocking etchant

Ultrasound

Generally speaking, ultrasound can really help etch reliability / smoothness by remove debris (see above) and by circulating solution to ensure even concentration.

Delayering for netlist extraction

An easy way to get good images from chemical etches (if multiple samples are available) is to throw a bunch of chips in the tank and take them out one at a time. This will allow different layers to be visible. If only one (or very few) samples are available the only option is to etch for a few minutes, then remove/rinse the specimen and inspect under a microscope to decide whether more etching is necessary.

Transistors

[bold-tech.com: Silicon Dioxide Etch] indicates that when using BOE, doped regions etch faster than non-doped regions.

ROM

See this page for background on ROM construction.

Ion implanted ROMs cannot be optically read by simply looking at top metal. However, they can be etched selectively (ex: contact based) or stained (ex: implantation) to be made visible.

“Smartcard 99” says: “The implant-mask layout of a NAND ROM can be made visible by a dopant-selective crystallographic etch (Dash etchand [Bec98]). This image shows 16×14 bits plus parts of the row selector of a ROM found on an MC68HC05SC2x CPU. The threshold voltage of 0-bit p-channel transistors (stained dark here) was brought below 0 V through ion implantation.”

Neviksti's comments on “DSP-1” page: “The Dash etchant worked for the NOR implantation rom (not the NAND rom, the opposite of what the paper claims). Which makes me wonder if they accidentally mentioned something else / mislabelled / whatever” (the paper being above quote from “Smartcard 99”). JM response: I've successfully stained NAND implant ROM. I haven't come across any NOR implant ROM yet

Determining sample thickness

Many solutions give distance per minute. Other than carefully observing when done, its useful to get some estimates to as how long etching takes. A couple of techniques:

Observation

Generally speaking its difficult to observe these solutions directly while etching for several reasons:

  • These solutions eat microscope objectives (mind vapors, not just the liquid)
  • Bubbles can rise from the solution, obscuring observation windows
  • Solution causes optical distortion. Additionally, bubble and evaporation cause the solution to change height and may require refocusing

The easiest way to get around these is to cover a microscope objective in Saran wrap. This allows the bubbles to pop and provides some fume protection. I still wouldn't do it with an objective you care that much about. This does degrade quality a little though. I've considered gluing a cover slide over but haven't tried it. In general I'd avoid direct observation (ie dip and check) unless you have a very good reason.

If checking samples under a microscope be sure to clean them thoroughly first. The hot microscope light will boil off any remaining solution leading to further unintended etching and possibly corroding your microscope. Be especially careful when etching metal layers as solution likes to hide under overhanging SiO2.

Anisotropy

Above left: metal floating off during HF etc. The SiO2 under it was completely eaten. Right: polysilicon gates that floated off after the SiO2 was undercut.

An isotrophic etch removes materially equally in all directions. Most wet etches are anisotropic because they remove any material they touch at constant rate. However, monocrystaline Si has planes that can be exploited to achieve some anisotropic etching. If you truly need anisotropic etching you should instead use RIE. That said, reasonably good results can often be had by etching to just where the metal stops and then etching away the metal with a separate solution. However, wet etching tends to be less consistent than RIE which still limits its use.

The isotrophic nature of wet etches generally limits wet etching to large feature sizes [JM experience, “Tools and Techniques” 149]. One thing to watch out for is beginning to undercut lower metal layers early from etching through vias. This can cause entire metal segments to lift off. Newer processes have this issue less because they use tungsten vias which tend not to etch as easily. [“Tools and Techniques” 148-149]

TODO: could we project light to achieve some degree of anisotropicity on the exposed surface? Unfortunately this has the best chance of working on Si (solutions are known to be photo-sensitive) where as this is mostly of interest on SiO2

Chemistry background

Silicon does not react with HF or many other things. Therefore, mixtures are used to create intermediates that can be processed. Having an understanding of this process helps to understand rates and how the mixture will react to different materials.

Oxidizing silicon to silicon dioxide

Silicon does not dissolve in most acids, including HF by means of the acid itself. However, oxidizing agents such as nitric acid convert it to silicon dioxiide [Friedrich Beck]:

3 Si + 4 HNO3 ⇒ 3 SiO2 + 4 NO + 2 H2O

Thus, exposed layers of elemental silicon are converted to silicon dioxide. Other oxidizing agents are potassium permanganate, hydrogen peroxide, iodic acid, and more.

Etching silicon dioxide

Usually we don't want just silicon dioxide but rather to remove it entirely. The most common way to do this is with HF [Friedrich Beck]:

SiO2 + 6 HF ⇒ H2SiF6 + 2 H2O

Don't recall any other SiO2 removing agents.

Dilutant

TODO: need more information on these

Using concentrated solutions, etch rates are typically too high. This means you have little reaction time and selectivity also tends to go down. There are three common dilutants: glacial acetic acid, water, and glycerine. Although water is readily available, it seems it is not preferred due to corrosion effects. Acetic acid is a liquid acid and glycerine is probably for when the pH should be kept more neutral.

Boron and Si

Tends to form borosilicate (which etchants?). Stops etching if boron concentration exceeds 1019 / cm3. [Wet-chemical Etching of Silicon]

Alkali etching

The idea is convert the silicon to silicate by using a liquid alkaline solution. Example reaction [Friedrich Beck]:

Si + 2 KOH + H2O ⇒ K2SiO3 + 2 H2

XXX: what if we used molten KOH? Maybe it wouldn't wash products away.

Optical

Optical excitation generates electronic by ejection?

Electrochemical

Putting positive voltage on Si in HF solution generates holes. [Fundamentals of microfabrication: the science of miniaturization]

Removing SiO2

HF

Straight HF will tear through Si quite readily

HF by itself will selectively etch SiO2 and various other compounds much faster than Si. Whink rust remover is an over the counter source of 3% HF (maybe 2% +/- 1%). HF can be synthesized from other chemicals, but is highly not recommended due to the extreme toxicity. For a chemical description of this reaction, see [bold-tech.com: Silicon Dioxide Etch]

Why use: selectively etch SiO2 over Si

Advantages

  • Simple
  • Can be used in combination with photoresist or similar masks to selectively remove filler over flash, etc. while preserving remainder of circuit
  • Materials may be readily available (as off the shelf rust remover)

Disadvantages

  • Solution can become depleted in certain areas leading to uneven etching
  • Materials may not be readily available in some areas
  • Metal layers may leave “shadows” in the oxide below
  • Concentrations and time must be monitored to get good slices of the die

NOTE: HF eats aluminum. This can be good or bad depending on the application. A quick search shows that HF only eats Cu with an oxidizer present (ie typically slightly so from atmosphere)

2.5% HF will require some heating to etch. Heat it but don't reach boiling as the fumes are still dangerous. It still various considerably from chip to chip, but expect etch times in the range of 20 minutes to get through the top passivisation and then maybe 2 or 3 minutes a layer after that. If in doubt do only very small runs at a time (< 30 seconds).

Example procedure

Procedure

  • Place die(s) in a plastic tray (see notes at top of page)
  • Add 3% HF to each specimen until top is completely covered
  • Wait 5-15 minutes, remove with plastic tweezers, and rinse

Alternate procedure

  • Place small beaker (10mL is ideal) of water on hot plate, heat to near boiling
  • Place die in plastic centrifuge tube
  • Apply ~1mL of 3% HF to tube, cap, place in water bath for heating
  • Remove from heat after 30 sec, suction HF with pipette. Rinse, inspect, and repeat if necessary.

Ammonium bifluoride (NH4HF2)

This essentially gives off HF when dissolved in water.

Buffered oxide etch (BOE)

More stable etching of silicon dioxide (SiO2) or silicon nitride (Si3N4) over, say 49% HF. Mixture [wiki: Buffered oxide etch]

  • Ingredients
    • 40% NH4F in water (6 mL)
    • 49% HF in water (1 mL)
  • Temperature: 25 C
  • Rate
    • Si (“thermally grown oxide”): 2 nm / s
    • SiO2: unknown
  • Notes
    • Adding HCl may reduce insoluble oxide bi-products

Staining

General notes

Most reactions are quoted to work better with a strong cold light. This evidently favors the decorating reaction over other side reactions. I haven't done a study to see how much this really matters.

Dash etch

Used for both decorating p areas as well as highlighting certain defects. In general, etch times are very short when used for decorating p areas (say 15 seconds) but it takes much longer to show crystallographic faults (say 12 hours). Can show epitaxial layers, doped areas and crystal faults [Beck].

Areas are initially stained brown (say up to 10 seconds). Longer exposures turns them blue. Beck says that strongly p-doped areas turn blue after 10-15 seconds [Beck 62] so I imagine that it really means they turn blue faster.

Above: samples before and after dash etchant. Left side: pre-etch, right side: post etch, top: brightfield, bottom: DIC. The original sample was visible only with DIC and P/N areas couldn't be distinguished. After decoration its clearly visible with simple brightfield illumination and DIC may now have made it less clear.

Above: left: unstained sample. Middle: light dash etching. Right: longer dash etching turns it blue-green.

For highlighting p regions

Use this to figure out of an area is N vs P stained.

“n-doped areas are scarcely attacked. p-doped zones are clearly brought out, and strongly p-doped areas change their colour from brown to blue after only 10-15 seconds…Epitaxial layers are also well shown.” Accelerated by light. Taking several hours, very slow / one of the slowest etchants. [Beck] For an example of staining ROMs see this

The chip should stain within a few seconds, 10-15 gives it plenty of time to make sure that everything sets well. However, the staining continues to change color with longer exposure so beware as n regions will also turn. It should be safe to ultrasonically clean the chip after staining if desired.

Equipment:

  • 100 mL PTFE beaker. Other HF resistant plastics should also work
  • 50 mL container to hold DI water
  • Clock
  • Plastic pipette
  • Optional: bright cold light. Fiber illuminator should work, I use a a high output LED bicycle light

Consumables:

  • 5 mL or so of Dash etch. I'm not sure how much is really needed but you should be able to comfterably cover the chip anyway
  • De-ionized (DI) water

Procedure:

  • Clean chip *thoroughly* (ultrasonic acetone-DI suds-IPA). Instead of dumping the IPA off and drying chip, instead rinse it with DI water. Do not let the chip ever dry out. Keep it submerged in DI water for the time being. If you suspect there is any grime on the chip you must clean it first or it will mask that region and may cause other complications. Using tap water suds may cause salt contamination, use de-ionized (DI) water
  • Rinse out beaker and container with DI water
  • Place chip on bottom of plastic beaker (I use 100 mL PTFE). Keep a few drops of DI water on it to keep it wet. They should stick with surface tension.
  • Fill second container with 50 mL DI water
  • Tilt beaker slightly with the chip on the raised side
  • Pippette 5 mL Dash etch into lowered side of beaker
  • Turn on bright light and point into beaker
  • Watch clock to hit the minute mark (or other easily rememberable spot). Slowly turn beaker 180 such that Dash etch will creep onto the chip without flipping it over
  • Let etch for 10-15 seconds
  • Dump the DI water into the beaker
  • Dispose of most of the solution in the beaker, making sure to not let the chip get dry. Wash the chip in the beaker a few times
  • Vortex chip in beaker for a couple of minutes. Experience has shown that if not thoroughly washed acid traces can stay on the chip and it will etch/expose over the next few days, sometimes resulting in deep gouges
  • Wash in IPA (ultrasound is safe) and blow dry

Notes:

  • I'm currently using “Structural etchants” mix since I now have 48% HF. Other mixtures may work just as well, I haven't revisited them since I got better at cleaning the sample
  • Tap water is not de-ionized!
  • All solutions/equipment must be copper free: HF solutions will readily deposit copper on the die and create a pesky mask. Reccomend using a dedicated metal free beaker

Mask ROM staining procedure

This isn't too hard but requires a great deal more attention than a lot of the other procedures on this site: the sample must be handled much more gently and the etching is time sensitive. I'm guessing that the doping is done a little different way such that it is much shallower than others making it easily damaged

Important things:

  • The sample must be very clean so as to not mask any etchants
  • Do not apply delayering etchant for longer than need be. It seems to slowly etch Si and/or pull out ions fast enough that it will lead to poor staining if it comes in contact with the implant for too long
  • Do not ultrasound the chip while delayering the ROM area. This causes things to break off more unpredictably and can lead to some areas etching a lot faster than others causing above problem to get worse

For normal ROM staining, optimal time to try dash is probably just a little after the polysilicon is lifted off of the ROM area. Poly may still be attached to the line drivers, don't worry if it is, they aren't important.

Experience has shown that this process is somewhat easy to get somewhat working but required some rigor for reliable results. Not all of these steps may be necessary but each one helps to control specific risks. I reccomend you do the above “highlight p regions” procedure first to get a basic hang of things.

Equipment:

  • 100 mL PTFE beaker. Other HF resistant plastics should also work
  • 50 mL container to hold DI water
  • Clock
  • Plastic pipette
  • Optional: bright cold light. Fiber illuminator should work, I use a a high output LED bicycle light

Consumables:

  • Buffered oxide etch (BOE)
  • 5 mL or so of Dash etch. I'm not sure how much is really needed but you should be able to comfterably cover the chip anyway
    • I'm currently using “Structural etchants” mix since I now have 48% HF. Other mixtures may work just as well, I haven't revisited them since I got better at cleaning the sample
  • De-ionized (DI) water

Procedure:

  • Decapsulate chip through your method of choice. Metal damage probably won't effect results too much
  • Clean chip *thoroughly* (ultrasonic acetone-DI suds-IPA). Instead of dumping the IPA off and drying chip, instead rinse it with DI water. Do not let the chip ever dry out. Keep it submerged in DI water for the time being. If you suspect there is any grime on the chip you must clean it first or it will mask that region and may cause other complications
  • Rinse out beaker and container with DI water
  • Perform etch cycles until the ROM area has no more SiO2 on it.
    • Place chip on bottom of plastic beaker (I use 100 mL PTFE). Keep a few drops of DI water on it to keep it wet
    • Fill second container with 50 mL DI water
    • Add 5 mL of BOE
    • Vortex chip for 30 seconds (or longer if you are feeling adventuresome). Do not use ultrasound
    • Dump the DI water into the beaker
    • Dispose of most of the solution in the beaker, making sure to not let the chip get dry. Wash the chip in the beaker a few times
    • Vortex in IPA and blow dry. Do not use ultrasound
    • Inspect under microscope to see if ROM active area is exposed
    • Notes
      • Remove metal layers as they are exposed, probably ideally just as you begin to undercut them. Ideally they probably should be removed before the mask ROM is exposed
        • Aluminum: remove using phosphoric acid at 50C for 5 minutes
        • Metal barrier: usually removed by “barrier etching solution”
      • You really should use BOE over HF: BOE doesn't eat metal which prevents hard to remove AlF salts from depositing on the die
      • If you are carefully watching it, you should see it change colors (when dry) and then turn clear once again which means its done
      • Initially you can probably get away with longer cycles (maybe a minute or two) but make sure to turn it down to 30 seconds max at a time if its already been a few minutes
      • Each round takes me about 10 minutes. I have lost a few chips to trying to save time by etching longer. Sometimes this saves time but sometimes it destroys the chip and is very frustrating. You are probably better off biting the bullet and just doing smaller cycles even if it takes you longer
      • I experimented with trying to observe the etch under microscope but found it was more hassle than it was worth for various reasons
      • There may be a large amount of field oxide left when its done
  • Fill second container with 50 mL DI water
  • Tilt beaker slightly with the chip on the raised side
  • Pippette 5 mL Dash etch into lowered side of beaker
  • Turn on bright light and point into beaker
  • Watch clock to hit the minute mark (or other easily rememberable spot). Slowly turn beaker 180 such that Dash etch will creep onto the chip without flipping it over
  • Let etch for 10-15 seconds
  • Dump the DI water into the beaker
  • Dispose of most of the solution in the beaker, making sure to not let the chip get dry. Wash the chip in the beaker a few times
  • Vortex chip in beaker for a couple of minutes
    • Experience has shown that if not thoroughly washed acid traces can stay on the chip and it will etch/expose over the next few days, sometimes resulting in deep gouges
  • Wash in IPA (ultrasound is safe) and blow dry

Notes:

  • Because of the field oxide, it can be difficult to get both a good stain on the ROM as well as to stain the general active areas on the same chip. If you have only one sample, stain the ROM, photograph it, and then use HF to remove the rest of the Fox. Re-stain the chip and the active areas should stain but you might lose the ROM staining. You could try masking it if you were really determined
  • If you over-delayer the chip it may not show up at first. You may still be able to get the data to show up, double the stain time and retry, giving up if you accumulate around 4 minutes
  • I'm currently using “Structural etchants” mix since I now have 48% HF. Other mixtures may work just as well, I haven't revisited them since I got better at cleaning the sample
  • Tap water is not de-ionized!
  • Over-delayering by 1 minute will likely destroy the data. The lower you can keep that number the crisper the data will be
  • All solutions/equipment must be copper free: HF solutions will readily deposit copper on the die and create a pesky mask. Reccomend using a dedicated metal free beaker

For crystallographic faults

When used for showing crystalgraphic faults, one of the oldest etchants and “not optimal in terms of selectivity and sensitivity”, 4-16 hours [Defect Etching in Silicon] When to use it: when you need good quality and can afford to wait up to a day.

Advantages:

  • Very good selectivity
  • Chromium free [Beck]
    • XXX: what issue would Cr cause?

Disadvantages:

  • Very slow (hours to near day)
    • FIXME: how does light intensity play into this?

"Structural etchants" mixture [Beck 60]

Recommended mixture:

  • 3 mL 65% HNO3
  • 1 mL 48% HF
  • 10-12 mL 98% HAc

Rate:

  • (111) Si @ 23C: 2 nm / min
  • Dislocation substrate etching: up to 24 hours
  • Section decoration: 120 seconds with light

JM Whink mixture

Adjusted from above to have roughly same ratio HF to HNO3

Mix:

  • 4 mL of stock solution
    • 0.5 mL 65% HNO3
    • 27 mL 2.5% HF
  • 11 mL Hac

Gave poor results in trial run but I suspect this may have actually been from incomplete SiO2 etching.

JM RustGo mixture

Adjusted from Beck to have same solution concentration of HNO3 and HF, then remainder filled with HAc. The NH4F2 is ignored. Although I don't know if its optimal, I have gotten good results with this solution.

Mix:

  • 3 mL 65% HNO3
    • 13% total solution
  • 4 mL 12% HF
    • 3.2%
  • 8 mL HAc
    • remainder

Staining Etch [Beck 74, 147]

Colors p-doped regions brown.

Advantages:

  • Can show depth of p-doped regions

Disadvantages:

  • High HF content causes strong SiO2 and polysilicon etch

General notes:

  • Adjust concentration based on expected doping level

Mixture: “Concentrated solutions are used to investigate weak diffusions, e.g. well diffusions, while dilute solutions are used for strong dopings” [Beck 147]. XXX: why are the concentrations opposite? Use 30-200 mL (48%) HF to 1 mL (65%) HNO3.

SD 1 etchant [Beck 73, 142]

When to use: “…the most suitable of all the crystal etchants for the joint display of doping areas in n-silicon”

Advantages:

  • Does not need to be made freshly

General notes:

  • Improved result when light present (accelerates process)
  • n becomes more rough than p
  • Not selective to orientation planes
  • This mixture will not show very strong: crystal defects, epitaxial layers, or oxide structures

Procedure:

  • Mix ingredients
  • Etch for 120 seconds

CP 6 etchant [Beck 73, 142]

When to use: when need to see both epitaxial and p-doped regions. “The etchant has proved particularly valuable for determining the position of the pn junction in power semiconductors”

Disadvantages:

  • Must be made freshly
  • Does not show crystal defects
  • Can show epitaxial layers but short etch time makes it difficult to use? (“epitaxial layers can be represented, but the etching times for this are very short”)

General notes:

  • Improved result when light present

Mix:

  • 31 mL 65% HNO3
  • 18 mL 10% Cu(NO3)2
  • 8 mL 98% HAc
  • “add 1.8 mL bromide per litre to this solution”

Procedure:

  • Mix ingredients
  • Etch for a few seconds

HF, Nitric, Acetic (HNA)

The most general purpose solution. Mixture

  • Ingredients
    • Glacial Acetic Acid: 11 mL
    • 70 % Nitric Acid: 7 mL
    • Hydrofluoric Acid 49%: 4 mL
  • Temperature: unspecified
  • Rate
    • SiO2: unknown
    • Si: unknown

Si

These are generally more useful for fab than anything else but are included here for completeness.

Tetramethylammonium hydroxide (TMAH)

WARNING: large TMAH exposure can cause sudden death

Mixture [Wet-chemical Etching of Silicon]

  • Ingredients
    • 25 % TMAH
  • Temperature: 80 C
  • Rate
    • Si
      • 37 (100) : 1 (111)
      • 68 (110) : 1 (111)
      • (100) Si: 0.3 - 1 um / min
    • Si3N4: < 0.1 nm / min
    • SiO2: 0.2 nm / min
  • Notes
    • Weakly anisotropic

Mixture [Wet-Chemical Etching and Cleaning of Silicon]

  • Ingredients
    • 20 % TMAH
  • Temperature: 79.8 C
  • Rate on Si (see source for detailed table)
    • (100): 0.604 um / min
    • (110):1.114 um / min
    • (210): 1.154 um / min
    • (211): 1.132 um / min
    • (221): 1.142 um / min
    • (310): 1.184 um / min
    • (311): 1.223 um / min
    • (320): 1.211 um / min
    • (331): 1.099 um / min
    • (530): 1.097 um / min
    • (540): 1.135 um / min
    • (111): 0.017 um / min

Ethylenediamine pyrocatechol (EDP)

Mixture [Wet-chemical Etching of Silicon]

  • Temperature
    • ? % EDP
  • Temperature: 110 - 115 C
  • Rate
    • Si
      • 20 (100) : 1 (111)
      • 10 (110) : 1 (111)
      • (100) Si: 1.25 um / min
    • Si3N4: 0.1 nm / min
    • SiO2: 0.2 nm / min
  • Notes
    • Toxic
    • Weakly anisotropic
    • Doesn't attack metals?

FB polysilicon etch 1 [Friedrich Beck]

Polysilicon selective etch solution. Mixture

  • Ingredients
    • 65% nitric acid (35 mL)
    • 40% HF in water (1 mL)
    • deionized water (14 mL)
  • Temperature: room (25C)
  • Rate
    • Polysilicon: ~550 nm / min

FB polysilicon etch 2 [Friedrich Beck]

Polysilicon selective etch solution. Mixture

  • Ingredients
    • 65% nitric acid (16 - 26 mL)
    • 98% acetic acid (12 - 23 mL)
    • 40% HF in water (1 mL)
  • Temperature: 20C
  • Rate
    • Polysilicon: ~150 nm / min
  • Notes
    • Requires constant stirring
    • Do not reuse solution
    • Selective against SiO2

FB polysilicon etch 3 [Friedrich Beck]

Polysilicon selective etch solution. Mixture

  • Ingredients
    • 65% nitric acid (2 mL)
    • DI water (60 mL)
    • 40% HF in water (3 mL)
  • Temperature: 23C
  • Rate
    • Polysilicon: ~150 nm / min
  • Notes
    • Requires constant stirring
    • Must be used fresh
    • Selective against SiO2

Potassium hydroxide, alcohol

Isopropyl alcohol based [Wet etching of silicon]

  • Ingredients
    • Isopropyl alcohol: 60% by weight
    • KOH: 40% by weight
  • Temperature: 80°C
  • Rate on Si
    • (100): 600 nm / min
    • (110): 100 nm / min
    • (111): 6 nm / min
  • Notes
    • May require heavy stirring, tends to separate
    • Isoproyl alcohol moderates / slows down reaction

Methyl alcohol based [Wet etching of silicon]

  • Ingredients
    • Water: 100 g
    • KOH: 50 g
    • Methyl alcohol: 40 g (30 mL)
  • Temperature: 50 - 60C
  • Rate for Si
    • FIXME: these rates seem too high, but thats what the page says. Maybe missing a u?
    • (100): 0.7 m / min</span>
    • (111): 0.035 m / min</span>
    • (110): “roughly 4 times that of the (111) direction”</span>
  • Notes
    • Suggests reflowing, especially since otherwise concentrations get out of proportion
    • KOH reactions with Si to produce H2, bubbles indicate damage in SiO2 if not expecting at given location

Applications

  • Anisotropic etch

Potassium hydroxide, water

Mixture [Friedrich Beck]

  • Ingredients
    • KOH (? mL)
    • Water (? mL)
  • Temperature: 60°C
  • Rate
    • 510 nm / min
  • Notes
    • Use fresh solution
    • Forms crystal patterns around exposed silicon, can be used to gauge effectiveness of solution
    • Careful not to overetch

Etch rates vary dramatically with temperature and concentration. Higher concentrations do not always etch faster, but may give a smoother etch.

Negligible attack on SiO2 and silicon nitride [http://cleanroom.byu.edu/KOH.phtml]

Pyrocatechol, an amine

“Etching by sequestering” [Friedrich Beck]

  • Amine examples
    • ethylendiamine popular
    • Hydrazine works (but is not technically an amine?)
  • Useful for etching monocrylstaline
  • Add pyrazine and water for related mixture
  • Rate: relatively slow

Schimmel etch

Based on Secco etch, supposedly better.

Mixture [Wet-Chemical Etching and Cleaning of Silicon]

  • Ingredients
    • Solution (1 mL)
      • CrO3: 75 g
      • 1000 mL H2O
    • 48 % HF (2 mL)
    • H2O (0 - 1.5 mL)

Mixture [AIR LIQUIDE ELECTRONICS CHEMICALS & SERVICES, INC. SCHIMMEL ETCH]

  • Ingredients (approx)
    • HF: 34 parts
    • CrO3: 5 parts
    • Water: 65 parts

Secco etch

Mixture [Defect Etching in Silicon]

  • Ingredients
    • HF (2)
    • H2O (1)
    • K2Cr2O7: 44 g per (1)
  • Notes
    • Works on all all types of silicon.

Mixture [Friedrich Beck]

  • Ingredients
    • 0.15 M K2Cr2O7 (1 mL)
    • 40% HF in water (2 mL)
  • Temperature: unspecified
  • Rate: unspecified
  • Notes
    • “According to [20] the mixture is appropriate, and even preferred, for grain-boundary structuring of polysilicon”

Seiter etch

Mixture [Defect Etching in Silicon]

  • HF: 1 HF for 9 H2O?
  • CrO3: 120 g per 100 mL of H2O

Etches defects very well on {100} surfaces, but nothing else

Sirtl etch

Mixture [Defect Etching in Silicon]

  • HF: 1 mL
  • H2O: 0.4 mL
  • CrO3: 0.2 mL

Etches {111}, but nothing else. Chart shows results on {100} though, so not sure how true this is.

When to use it: “particularly suitable for displaying crystal disturbances in <111> silicon and produces large, sharply bounded etch pits in a short time…The preferred area of use for the Sirtl etchant is the display of stacking faults…, dislocations and sailing-boat faults” [Beck]

Advantages:

  • “higher etch rate than other popular etch-pit corrodents” [Beck]
  • “can be used to obtain sharply delimited etch pits with little surface disturbance on bare silicon surfaces with various crystal orientations in a relatively short time” [Beck]

Disadvantages:

  • Does not keep / must be made fresh

Beck

When to use it: “particularly suitable for displaying crystal disturbances in <111> silicon and produces large, sharply bounded etch pits in a short time…The preferred area of use for the Sirtl etchant is the display of stacking faults…, dislocations and sailing-boat faults”

Chemistry (from Sirtl/Adler): 4 Cr + 24 H+ + 12 F- + 3 Si ⇒ 4 Cr+3 + 12 H2O + 3 SiF4

First add HF and then stock solution.

Stock solution

Mixture

  • 25 g CrO3
  • 75 mL DI H2O

Keep sealed after mixing.

Large etch pit

Mixture

  • 1 mL stock solution
  • 2 mL 48 % HF

Rate

  • Dislocation substrate etch: 15 min
  • Section decoration w/ light: 20 sec
  • 1.3 um / min

Medium etch pit

Mixture

  • 1 mL stock solution
  • 1 mL 48 % HF

Rate

  • Dislocation substrate etch: 15 sec to 10 min
  • Section decoration w/ light: 10 - 20 sec
  • 1.3 um / min

Small etch pit

Mixture

  • 3 mL stock solution
  • 2 mL 48 % HF

Rate

  • Dislocation substrate etch: up to 10 min
  • 1.3 um / min

Wright etch

Mixture [Defect Etching in Silicon]

  • HF (concentrated) (1)
  • CrO3 (0.5)
  • H2O (1)
  • HNO3 (0.5)
  • Cu(NO3)2: 2 grams for 60 ml H2O
  • 1 unit acetic acid

Why copper nitrate helps is unknown. Not sure what types of silicon this works on, maybe all.

Decoration as called by Fredrick Beck is the process of making parts stand out better.

Copper sulphate

Copper sulphate will bring out n-diffusion areas of pn junctions when illuminated (FIXME: how strong?). Chemistry is something like:

Cu+2 + 2 e- ⇒ Cu

Si + 4 HF + 2 CuSO4 ⇒ SiF4 + 2 Cu + 2 H2SO4

At higher temperatures, HF etch takes over, so it needs to be done cold. In particular, do not use a hot light source such as a bare halogen lamp. If it goes through a microscope it should be fine as the thermal part should be heavily attenuated / distorted by the time it reaches the sample.

Periodic Acid Etchant

Good at showing where doping changes. Strong etch rate dependence on illumination. Room temp: mostly etches highly doped areas, especially p+ with max conc 1018 atoms / cm3 Increased illumination favors weaker doping.

  • 20-50 seconds
  • 50 mL H2O
  • 5 g H5IO6 (periodic acid)
  • 5 mg KI
  • 2 mL 48 % HF
  • Must be added in given order

Permanganate Etchant

3 mL KMnO4

97 mL 48 % HF

5.5 um / min on <111> @ 23C

Bichromate Etchant

Brings out n doped areas. Use 1:10 diluted Secco etchant. : H2O

Silicon etchant p

  • 20 mL acetic acid
  • 1 mL 40% HF
  • 3 mL 65% HNO3
  • 1-3 seconds

Staining etchant

  • 12 mL 65 % HNO3 (works without nitric if just exposed to air?)
  • 200 mL 48% HF
  • 5-10 seconds

Doping etchants

These enchants are intended to be used to highlight either P or N

Many delayering solutions become increasingly structural as the light level increases. They are more selective at lower temperatures, so try to use a cold light, ie an LED and not a halogen. Of course, if you can put an IR shield, you can use a halogen just fine. Microscope optics might do this already.

Copper sulphate

Selective towards: n-Si

Mixture [Friedrich Beck]

Ingredients

  • CuSO4 * 5 H2O: 8 g
  • 48 % HF: 10 mL
  • DI water: 980 mL

Rate: 5 - 30 seconds

Mixture

Based on above, but adjusted for off the shelf acid.

Ingredients

  • CuSO4 * 5 H2O: 1 g
  • 2.5 % HF: 24 mL
  • DI water: 100 mL

Rate: 5 - 30 seconds

Calculations

  • This is very approx, I don't know volume of HF and I assume its negligible
    • wik says 1.15 g/mL for 48% soln
  • Original: 48 g / 100 mL ⇒ 48 g
  • Have: 2.5 g / 100 mL ⇒ 2.5 g
  • 192 mL of 2.5 % for equal mass
  • 990 mL original solution, - 190 mL ⇒ 800 mL of water
  • Reduced by factor of 8

Metals

Al

Beck reccomends 65% phosphoric acid to remove aluminum: “65%, application at 50C. Etch rate 0.2 mm/min. Very uniform attack, also very gentle to oxides and silicon.” Since a layer is rarely more than 2 um thick it should take just a minute to completely remove the layer. If you are having problems completely removing it there may be a metal barrier, see “Beck barrier Ti/TiN solution” (TODO: add pictures)

Au

Use aqua regia

Ti

Aqua regia does not react with Ti, use “Barrier Ti/TiN etch”

Barrier

Beck barrier etching solution

Mixture [Beck 45]:

  • 9 mL 30% H2O2
  • 2 mL NH4OH
  • ~3 min @ 50-55C

Notes:

  • Reaction is exothermic and may heat up very hot. Moderate in water bath if having problems
  • Seems to also react at room temp. You should be able to see more vigorous bubbling if its actually reacting. Its harder to see this at higher temps because the H2O2 will also decompose faster on its own
  • Does not react with Ti?

Beck barrier Ti/TiN solution

Belive this is a more agressive version of above that also attacks Ti (and others?)

Mixture [Beck 45]:

  • 200 mL 65% HNO3
  • 1 mL 40% HF
  • 20-25 @ room temp

Notes:

  • I haven't used this solution yet

References

 
delayer/wet.1378020753.txt.gz · Last modified: 2013/10/20 14:59 (external edit)
 
Except where otherwise noted, content on this wiki is licensed under the following license: CC Attribution 4.0 International
Recent changes RSS feed Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki